Out of service
—Manual shutdowns, automatic shutdowns and machines under repair, as in DatPro2 OutOfOrder1. Newest changes appear first. Managers with Unit Write can return a machine to service.
Connect to view your machines, or try the demo.
Machine cards will appear here.
API endpoints used by this example
POST /api/v1/session/loginandPOST /api/v1/session/renew— shared manager bearer login.GET /api/v1/units/out-of-service?pageSize=100— all current nonzero OutOfOrder settings, with cursor paging.POST /api/v1/units/{unitKid}/out-of-service/restore— send{"expectedRevision":"revision from list"}to set OutOfOrder to Enabled (0).
The API excludes SMS types and disabled locations and enforces resource and retention permissions. It reads the original packed UnitType only. This selection is separate from AutoOutOfOrder alerts and the public machine-error widget.
Return to service records the change in Log2 and verifies Log24. It does not start a machine, clear its recorded error or confirm device acknowledgement. A changed revision returns 409. After an uncertain POST result, refresh and check the status before trying again. POST is never automatically retried.